LGT-100 Cross Stack & In-Situ Laser Gas Analyzer
#in #situ #gas #analyzer
Overview Of LGT-100 Cross Stack & In-Situ Laser Gas Analyzer
LGT-100 in-situ gas analyzer is a flameproof in-situ probe-type tunable laser gas analyzer for industrial online analysis and environmental on-line monitoring, which can online analyze O2, CO, NH3, CO2, CH4, H2O, HCl, HF and other gases in various complex conditions (NOTE: A single analyzer can only analyze 1~2 components). The measuring concentration of this type of gas analyzer equipment range from major to trace.

Features Of LGT-100 Cross Stack & In-Situ Gas Analyzer

• LGT-100 in-situ gas analyzer has easy optical path adjusting, XY direction non-coupling adjusting.
• LGT-100 in-situ gas analyzer has a small drift, long maintenance period, drift ≤ 1%F.S./half year.
• LGT-100 in-situ gas analyzer uses "Single line" spectrum technology, free from the interference of background gas.
• LGT-100 in-situ gas analyzer has integrated structure design, high stability, and reliability.
• LGT-100 in-situ gas analyzer has integrated flameproof structure, consuming less purge gas compared with positive-pressure mode.
• LGT-100 in-situ gas analyzer uses in-situ measurement without a pretreatment system which avoids adsorption, blockage, and damage reduces cost.

Application Of LGT-100 Cross Stack & In-Situ Gas Analyzer

LGT-100 in-situ gas analyzer manufactured by CEMS manufacturers like ZETIAN, can be applied to converter gas recovery gas analysis, CDQ circulating gas analysis; oxygen measuring electric fishing coke oven gas after analysis; pulverized coal injection gas analysis; ammonia escaping gas analysis in the cement industry; trace CO detection and analysis electricity, cement, environmental protection; HCl and HF trace analysis in environmental protection and chemical industry.

Technical Parameter Of LGT-100 Cross Stack & In-Situ Gas Analyzer

Principle TDLAS
Linearity Error ≤±1%F.S.
Span Drift ≤±1% F.S./half year
Zero Drift ≤±1% F.S./half year
Calibration cycle 2 times/year
Response Time ≤1s(T90)
Explosion proof ExdIICT6 Gb
Analog Output 2× 4-20mA output
Analog Input 2× 4-20mA input
Digital Communications RS485/RS232/GPRS
Working Temp -20℃~+60℃
Purge Gas 0.3MPa ~ 0.8MPa N2, clean air
Power supply 24VDC,