Commercial DC Inverter Heat Pump (18KW/25KW/30KW)

#inverter #driven #heat #pump

Product DescriptionSpecification
DC Inverter Driven Heat Pump Overiew
Famous world name brand parts: DC inverter MITSUBISHI Compressor and HITACHI DC inverter controller, BLDC fan motor to sure running high efficiency, R410A refrigerant without pollution. 380V/3Ph/50Hz or 60Hz power supply.

Heating more bigger around 200sq ~400sq meter room in Winter, and cooling around 250sq~480sq meter room in summer.

The inverter air source heat pump can change the fixed frequency of 50 Hz to120 Hz operation frequency by means of inverter controller. It is able to adjust the compressor at any time according to the environment, the frequency of the power supply of the fan, adjust the compressor, the speed of the fan, and realize the stepless speed adjustment, so as to make use of the energy reasonably.

EVI dc inverter heat pump can lower the current when the system starts, and will not impact the power grid and watt-hour meter. It can reduce interference to other electrical appliances in the room. The voltage adaption range is 340V - 420V, which solves the problem of unstable work due to voltage instability. The wider the frequency range is, the more reliable it can be ensured to operate in continuous working conditions, and the more obvious the advantage of energy saving is. Fast refrigeration(or heating), the good heating effect at low temperature.

The inverter driven heat pump can achieve high power and high efficiency. When the system starts, or when the temperature of the environment is different from the set temperature, it can run at the maximum frequency, which can reach 120 Hertz. It begins heating quickly, the temperature rises or drops rapidly to the set temperature, and the temperature environment can be quickly obtained. When the temperature reaches the set value, it automatically turns to the low-frequency operation, and the heating (cooling) effect is obvious.

In addition, in winter, because of the low ambient temperature, the air source heat pump will become frequently frost, and the heat capacity of the air will be greatly reduced. Inverter air source heat pump can defrost at high frequency, which greatly reduces the defrosting time and greatly improves the heat production.

The variable frequency air has good adaptability to environment temperature, good performance at low temperature, and no "attenuation" in the low-temperature environment of -15 degree through the technology of non-pole frequency conversion, and the thermal performance is obviously better than the constant frequency and low-temperature air energy. High efficiency and energy saving, low noise and long life, the air source heat pump can determine the operating frequency of compressor and fan based on how much heat (cold) needs, so as to make use of energy reasonably. And because the compressor does not open frequently, it will keep the compressor working state stable, so it will not consume much electricity energy. The energy efficiency of COP can be more than 30% of the total energy consumption of the fixed frequency air, and at the same time, it will play a significant role in reducing the noise and prolonging the service life of the air energy.

The biggest advantage of air source water heat pump is energy saving. Heat pump heating is only 0.28 degrees per flat meter per day, only 0.14 yuan per day, air conditioning heating, less square meters per day saving nearly 60%. Compared with the gas wall hanging furnace, for one 100 square meters of housing, if we need to guarantee the normal indoor temperature of one day above 20 degrees Fahrenheit, it requires 15 cubic meters of gas. According to the calculation of 2 yuan per cubic meter, the cost of one day is about 30 yuan, and the air source heat pump heating cost is less than 20 yuan, and it is also very energy-saving. Compared with the heating cost of 6.5 yuan per square meter, air energy heat pump heating can save energy more than 90%, so its advantage is more obvious.
Air Source Inverter Heat Pump Specification
Commercial DC inverter heat pump --Heating in Winter + Cooling in Summer

Model

RSV-18A/S
RSV-25A/S(C)
RSV-30A/S(C)


HP
8P
10P
12P

Power supply
V/Hz 
380V/50Hz

Cooling
Rated cooling capacity
kW
18.0 
25.0 
30.0 


Rated cooling input power
kW
5.6 
7.6 
9.4 


EER
w/w
3.2
3.3
3.2


Cooling Min / Max
kW
9.0/24.0
11.0/32.0
13/38


input power Min / Max
kW
2.4/9.0
3.0/12.2
3.6/15.0


EER Min / Max
w/w
2.2/4.2
2.2/4.2
2.2/4.2

 Heating
Rated heating capacity
kW
20.0 
27.0 
33.0 


Rated heating input power
kW
5.8 
7.8
9.7


COP 
w/w
3.4 
3.5 
3.4 


Heating capacity Min / Max 
kW
10.0/24.0
12.5/32.0
15.0/38.0


Input Power Min / Max 
kW
2.4/9.0
3.0/12.2
3.6/15.0


COP  Min / Max 
w/w
2.7/4.6
2.7/4.6
2.7/4.5

Refrigerant
Type
R410A

Heating hot water temp. rang

30℃~50℃

Cooling cold water temp. rang

5℃~20℃

Working ambient temp.

-20℃ (or-25℃ optional )~45℃

Compressor
Type
Scroll MITSUBISHI DC inverter 

Controller system
Type
Hitachi DCBL controller  

Throttle way
Type
Electronic expansion valve

Fan motor
Type
Brushless DC Motor

Pressure device
Type
 Built-in high and low pressure sensor

Electronic Component
Type
Schneider AC contactor

Fan QTY

two small fan
one big fan

Noise
dB(A)
57
60
62

N.W/ G.W
Kg
150/175
290/310
310/340

Connect pipe size
inch
Rc1-1/4" /DN32
Rc1-1/2" / DN40

Unit Size (L*W*H)
mm
1060*420*1560
1300*780*1840
1300*780*1840

The data in the above table test as following :
1. Heating test condition: ambient temp. (DB/WB):7℃/6℃,inlet/outlet water temp.:40℃/ 45℃ 
2. Cooling test condition : ambient temp. (DB/WB): 35℃/24℃,inlet/outlet water temp.:12℃/ 7℃ ;                                                        
Note : the data in this table are for reference only, please following the nameplate parameter of this product .
http://www.sunchienergy.com/commercial-dc-inverter-heat-pump-18kw-25kw-30kw.html